Menu Close

What is ASTM B117 standard?

What is ASTM B117 standard?

ASTM B117 salt fog or salt spray testing is a very popular corrosion test designed to provide corrosion resistance information on metals and coated metals. The ASTM B117 test standard has also been approved for use by Department of Defense agencies.

How do you perform a salt spray test?

Salt spray tests are conducted in a closed testing chamber. A salt water solution is applied to a sample via a spray nozzle. This dense salt water fog is used to imitate a corrosive experiment. After a period of time, which is dependent on the corrosion resistance of a product, the appearance of oxides is evaluated.

Is code for salt spray test?

salt spray tests prescribed in IS : 5528-1985*, IS : 6910-19857, and IS : 9844-1981:. This apparatus may be used for corrosion testing of decorative coatings of copper plus nickel plus chromium or nickel plus chromimum and anodic coatings on aluminium.

What are salt spray hours equivalent to in years?

I don’t want to bore you with more test methods, but as you can see there are reasons for tests other than salt spray. My references indicate that approximately 100 hours salt spray is similar to one year outdoors based on OEM testing in the US.

What is neutral Salt Spray?

Neutral Salt Spray, or NSS, refers to traditional salt spray testing in which the pH of the solution is 6.5-7.2. Copper-accelerated acetic acid salt spray, or CASS, refers to a more corrosive test in which chemicals are added to the salt water solution resulting in a pH of 3.1-3.3.

What is ASTM B633?

The most common standard for zinc plating is ASTM B633, which has four classifications for electroplated zinc. Each classification specifies which supplemental treatment or chromate to apply (Type I,II,III,IV,V, or VI) and the plating thickness according to the type of environment (SC1, SC2, SC3 or SC4).

What is SST in powder coating?

Salt Spray Test (SST) is a really widespread corrosion method, applied in order to check materials and surface coatings corrosion resistance.

What is NSS in salt spray test?

NSS Testing Method NSS or Neutral salt spray test is a quality assurance test conducted on coated, painted, electroplated, or galvanized material. It is conducted using a standardized salt spray testing machine in which salt water (5% NaCl) solution is atomized by means of spray nozzle using pressurized air.

What is a 1000 hour salt spray test?

The Salt Spray Test is a standardized test which allows one to compare the relative corrosion resistance of different coatings in conditions that try to mimic the true corrosive environment.

What is CASS test?

The Copper Accelerated Acetic Acid Salt Spray (CASS) test method is an aggressive accelerated corrosion test used to determine corrosion resistance of various aluminum alloys and for testing chromium plating on zinc and steel die castings.

What color is ASTM B633 Type II?

Zinc Chromate Per ASTM B633-85 Type II Does the Type II in spec ASTM B633 [affil. link to spec at Techstreet] designate the color Zinc Yellow.

Is ASTM B633 Type II RoHS compliant?

ASTM B633-11 now addresses RoHS compliance.

What is the purpose of salt fog test?

The salt spray test (or salt fog test) is a standardized and popular corrosion test method, used to check corrosion resistance of materials and surface coatings.

How do I prepare for Cass?

Our Tips for CASS which is a key point :- “Be Honest “ while answering question related to Personality. b) Structured Interview – Non-formal Interview of 20 to 30 min with CAE panelist. No technical knowledge is tested in this part. c) Physical Task is of roughly around 1 hour 15 minutes.

What is used in Cass?

The CASS solution per ASTM B368 consists of a standard ASTM B117 salt solution of 5 parts (by weight) of salt to 95 parts water with the addition of reagent grade copper chloride dihydrate at a rate of 1 gram to 4 litres of salt solution.

Is black zinc plating RoHS compliant?

The solution ITT Cannon’s Black Zinc Nickel is a RoHS-compliant, cost-effective and sustainable plating alternative to Cadmium. Black Zinc Nickel Plating offers the same level of harsh environment protection, temperature ranges and electrical performance as Cadmium finishes.

Does RoHS apply to stainless steel?

Is stainless steel RoHS compliant? Yes. Although chromium is present in stainless steel, it’s not the hexavalent chromium restricted by RoHS.

What is Cass exam?

A Copper Accelerated Salt Spray Test (CASS Test) is a test used to determine the resistance to corrosion of aluminum alloys. The test also is used to determine the corrosion resistance of chromium plating found on steel and zinc die casings.

How can I prepare for IndiGo cadet pilot?

Application Process

  1. Visit www.cae.com and select training programs.
  2. Select IndiGo cadet program from the menu.
  3. Complete and submit the enrollment questionnaire and registration form.
  4. A representative will be in contact to review your application and answer any question you may have.